Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Rev. bras. ortop ; 51(6): 672-679, Nov.-Dec. 2016. tab, graf
Article in English | LILACS | ID: biblio-830012

ABSTRACT

ABSTRACT OBJECTIVES: To evaluate through the visual analog scale (VAS) the pain in patients undergoing total knee replacement (TKR) with different pressures of the pneumatic tourniquet. METHODS: An observational, randomized, descriptive study on an analytical basis, with 60 patients who underwent TKR, divided into two groups, which were matched: a group where TKR was performed with tourniquet pressures of 350 mmHg (standard) and the other with systolic blood pressure plus 100 mmHg (P + 100). These patients had their pain assessed by VAS at 48 h, and at the 5th and 15th days after procedure. Secondarily, the following were also measured: range of motion (ROM), complications, and blood drainage volume in each group; the data were subjected to statistical analysis. RESULTS: After data analysis, there was no statistical difference regarding the incidence of complications (p = 0.612), ROM (p = 0.202), bleeding after 24 and 48 h (p = 0.432 and p = 0.254) or in relation to VAS. No correlation was observed between time of ischemia compared to VAS and bleeding. CONCLUSIONS: The use of the pneumatic tourniquet pressure at 350 mmHg or systolic blood pressure plus 100 mmHg did not influence the pain, blood loss, ROM, and complications. Therefore the pressures at these levels are safe and do not change the surgery outcomes; the time of ischemia must be closely observed to avoid major complications.


RESUMO OBJETIVOS: Avaliar, por meio da escala visual analógica (EVA), a dor em pacientes submetidos à artroplastia total do joelho (ATJ) com diferentes pressões do torniquete pneumático. MÉTODOS: Foi feito um estudo observacional, descritivo, de caráter analítico, prospectivo, randomizado, no qual 60 pacientes foram submetidos à ATJ, divididos em dois grupos, os quais foram comparados entre si: um grupo no qual a ATJ foi feita com pressão do torniquete de 350 mmHg (Padrão) e outro com 100 mmHg acima da pressão arterial sistólica (P + 100). Esses pacientes tiveram sua dor aferida pela EVA após 48 horas, no quinto e no 15° dias após o procedimento cirúrgico. Secundariamente, foram medidos também a amplitude de movimento (ADM), o sangramento via dreno suctor e as complicações em cada um dos grupos estudados; os dados foram submetidos à análise estatística. RESULTADOS: Após a análise dos dados, não foi constatada diferença estatisticamente significante em nível de 5% de significância da pressão em relação à incidência de complicações (p = 0,612), ADM (p = 0,202), ao sangramento após 24 e 48 h (p = 0,432 e p = 0,254) e à EVA. Também não foi constatada correlação do tempo de isquemia em relação a EVA e ao sangramento. CONCLUSÕES: As pressões usadas do torniquete pneumático, 350 mmHg ou pressão arterial sistólica + 100 mmHg, não tiveram influência sobre a dor, a perda sanguínea, a amplitude de movimento e as complicações, são pressões seguras que não alteram o resultado final, desde que respeitados o tempo da isquemia e individualizados os casos.


Subject(s)
Humans , Male , Female , Arthroplasty, Replacement, Knee , Pain Measurement , Tourniquets
2.
Rev. bras. ortop ; 51(5): 547-554, Sept.-Oct. 2016. tab, graf
Article in English | LILACS | ID: biblio-829995

ABSTRACT

ABSTRACT OBJECTIVES: To evaluate bleeding and the estimated blood loss in patients who underwent total knee replacement (TKR) with different closed suction drains (3.2-mm and 4.8-mm gauge). METHODS: This was a randomized controlled trial with 22 patients who underwent TKR and were divided into two groups: Group I, with 11 patients in whom the 3.2-mm suction drain was used, and Group II, with 11 patients in whom the 4.8-mm suction drain was used. The hematocrit was measured after 24, 48 and 72 h after surgery in order to calculate the estimated blood loss. The drained volume was measured 3, 6, 12, 24, and 48 h after TKR, and thereafter both groups were compared. RESULTS: Regarding the hematocrit, there were no differences between groups in measured periods (24, 48, and 72 h after surgery). The total bleeding measured at the suction drains within 48 h was higher in Group II, with a statistically significant difference (p = 0.005); in the first 24 h, there was major bleeding in Group II (mean 893 mL), with a significant difference (p = 0.004). Between 24 and 48 h, there was no statistically significant difference in both groups (p = 0.710). The total estimated bleeding was higher in Group I, with mean of 463 mL, versus 409 mL in Group II, with no statistical significance (p = 0.394). CONCLUSIONS: Bleeding was higher in the group that used the 4.8 mm gauge suction drain, with no differences in hematocrit and estimated blood loss.


RESUMO OBJETIVOS: Avaliar o sangramento através do dreno suctor (DS) e a perda sanguínea estimada em pacientes submetidos à artroplastia total do joelho (ATJ) com DS de diferentes calibres (3,2 mm e 4,8 mm). MÉTODOS: Ensaio clínico randomizado com 22 pacientes submetidos à ATJ, divididos em dois grupos; no grupo I, os pacientes recebiam o DS 3,2 mm e no Grupo II, o DS 4,8 mm. O hematócrito foi aferido 24, 48 e 72 horas após a cirurgia, a fim de calcular a perda sanguínea estimada. O débito do dreno foi medido 3, 6, 12, 24 e 48 horas após a ATJ e os dois grupos foram comparados. RESULTADOS: Em relação ao hematócrito, não se observaram diferenças estatisticamente significativas entre os grupos nos períodos aferidos (24, 48 e 72 horas pós-operatória). O sangramento total medido no DS nas 48 horas foi maior no grupo II, com diferença estatisticamente significativa (p = 0,005); nas primeiras 24 horas, houve maior sangramento no grupo II (média 893 mL), com diferença significativa (p = 0,004). Entre 24 e 48 horas, não foram observadas diferenças estatisticamente significativas em ambos os grupos (p = 0,710). O sangramento total estimado foi maior no Grupo I, com média de 463 mL, enquanto no Grupo II esse valor foi de 409 mL, sem significância estatística (p = 0,394). CONCLUSÕES: O sangramento foi maior no grupo que usou DS 4,8 mm, sem diferenças no hematócrito e na perda sanguínea estimada.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Arthroplasty, Replacement, Knee , Blood Loss, Surgical , Drainage
SELECTION OF CITATIONS
SEARCH DETAIL